SINGLE TIMER
L205A
DUAL TIMER
L214A
SOLID-STATE TIMER ADJUSTMENT:
A factory pre-set electronic solid-state timer controls the volume of water for each
brew cycle. If more or less water is desired, follow these instructions:
Turn knob of timer clockwise to increase volume of water or counterclockwise to decrease it. Run through a complete
brew cycle after each adjustment. Since timer cannot be readjusted in mid-cycle, simply push cycle stop switch at bottom
right of side box if water gets too high. If maximum setting of timer fails to deliver enough water, check water pump and
spray head and follow instructions under maintenance.
MECHANICAL TIMER ADJUSTMENT (ALL CL's & CH's): The factory pre-set mechanical timer can be adjusted for more
or less water by following these instructions:
Remove timer knob and loosen lock nut holding stop pin. To increase volume of water, rotate stop pin clockwise. To
decrease, rotate counterclockwise. Tighten lock nut and replace knob.