10SLEEP TIMER SLEEP TIMER ON/OFF Description – The Sleep Timer feature automatically reduces the water temperature to three degrees above the Lockou
11ADJUST SECONDS ADJUST SECONDS DAY HH:MM:## Description – The Adjust Seconds function allows the user to adjust (set) the systems Real-Time-Clock S
12 ERROR MODE Description – The main function of Error Mode is report any system
13 TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal
14SPECIAL COMPONENTS TEST AND ADJUSTMENTS 1) WATER INLET VALVE (SOLENOID) TEST (Located inside bottom cabin) Turn power off from touchpad. If t
155) CHECK DISPENSE VALVES FOR LIME BUILD-UP (Located inside top cabin) Drain The Water Tank To Just Below The Level Of The Dispense Valves. Remo
16 PARTS IDENTIFICATION BC301-IT BC2-IT BC302-IT ITEMP/N QTY P/N QTY DESCRIPTION 1 SF26A 1 S
TOP CABIN - PARTS IDENTIFICATION ITEM P/N BC301-IT QTY P/N BC2-IT BC302-IT QTY DESCRIPTION 1 L069A 1 L069A 1
OTTOM CABIN - PARTS IDENTIFICATION ITEM P/N BC301-IT QTY P/N BC2-IT BC302-IT QTY
19 CARRIER ASS’Y 97208 [* RECOMMENDED SPARE PARTS] Item Description Part # 1 * Han
2SPECIFICATIONS ELECTRICAL SPECIFICATIONS MODEL NO. BC301-IT BC2-IT BC302-IT Volts 120/230 120/230 120/230 Watts 4100 6200 6200 Amps 18 27 27 Wall
3FEATURES AND BENEFITS OF THE DIGITAL, MEMBRANE CONTROL TOUCH PAD BREWER 1. 100% Solid State Control for improved reliability. 2. Modular design
4INSTALLATION AND OPERATING INSTRUCTIONS Warranty is void if the Brewer is connected to any Voltage other than the Voltage specified on the data lab
5PROGRAMMING INSTRUCTIONS The following is a Functional Description of the Single Station Brewer: Modes of Operation - Ov
6MODES OF OPERATION – DESCRIPTIONS Initialization Mode: The following screen signifies the presence of this mode: CECILWARE &&&&&
7Description – The Brew Fill Constant Calibration State is entered from the Heating State or the Ready State by simultaneously pressing the [Down Arr
8SERVICE MODE Description – The main function of Service Mode is to give qualified personnel the ability to configure the system to meet the require
9SOAK TIME SOAK TIME ## SECONDS Description – The Soak Time is the amount of time that the system will wait between the end of the hot water infusio